NEMA14 Integrated Stepper Motor with Multi-ring Absolute Encoder
multi-ring absolute encoder
The IS14 series integrated motor is the perfect combination of drive and stepper motor,
which perfectly integrates stepper motor and drive technology, also built in a battery free
1023 turn mechanical absolute value encoder, it can save installation space,
Simultaneously saving design and production costs, supporting RS485 instruction control.
Item | Specifications |
Stepper Motor Size | NEMA14 |
Encoder type | 1023 ring absolute encoder |
Working voltage | 8-36V |
Driver Current | 0.2-2.0A |
Velocity range | Up to 3000RPM |
Control Method | RS485 √ Pulse& Direction, Twin-Pulse, I/O, Built-in Program |
Torque value | 0.1 - 0.4Nm |
Nonvolatile storage | Configuration parameters are stored in FLASH inside the MCU |
DI and DO | 2 DI, 1 DO |
Protection | Overvoltage, undervoltage, overcurrent, open winding, position deviation |
Digital Input (2) | Receive 3.3-24VDC | ||
Digital Output(1) | Maximum withstand voltage of 30V, | ||
Maximum input or output current 30mA |
Motor Parameters
Model No. | length mm L | Shaft length mm | Shaft dia. mm | Phase current A | Resistance Ω | inductance mH | Hold torque N.m | Inertia g.cm² | Weight g |
IS14010 | 52 | 24 | 5 | 1.0 | 2.55 | 2.0 | 0.1 | 12 | 240 |
IS14020 | 62 | 24 | 5 | 1.5 | 1.65 | 2.1 | 0.2 | 20 | 300 |
IS14040 | 80 | 24 | 5 | 1.8 | 1.85 | 2.8 | 0.4 | 35 | 350 |
Wiring Diagram:
Terminal Definition
Terminal | Name | Description | |
1 | V | 8-36VDC | |
2 | V- | GND | |
3 | X0 (PU ) | Optoelectronic isolation, differential, High level can directly receive 3.3-24VDC, with a minimum pulse width of 2us, The maximum pulse frequency is 400KHz, which can be used as a universal input port for Pulse/Direction | |
4 | X0-(PU-) | ||
5 | X1 (DR ) | ||
6 | X1-(DR-) | ||
7 | X2(EN ) | Optoelectronic isolation, differential, High level can directly receive 3.3-24VDC, with a minimum pulse width of 100us, The maximum pulse frequency is 10KHz, which can be used as a universal input port for Enable | |
8 | X2-(EN-) | ||
9 | Y0 (AL ) | The default alarm output port can detect the driver alarm status and provide feedback to the main station. Other functions can be set through communication | |
10 | Y0-(AL-) | ||
11 | 485A | RS485 Communication port, default baud rate is 115200 | |
12 | 485B |
Block Diagram:
2 Input signals can directly receive 3.3-24V DC levels at high levels, Max. frequency of 400KHZ.
X0: pulse input, IO start/stop, limit, direction, universal input.
X1 pulse input, IO start/stop, limit, direction, universal input.
1 Output signal, maximum withstand voltage 30V, maximum input or output current 30mA
Y0 : alarm output, universal output, and factory default alarm output.
LED indicator and status:
CRC Check routine by C# :
Uint16 Funct_CRC16(unsigned char * puchMsg, Uint16 DataLen)
{
Uint16 i,j,tmp;
Uint16 crcdata=0xFFFF;
for(i=0;i<DataLen;i )
{
crcdata=(*puchMsg)^crcdata;
puchMsg ;
for(j=0;j<8;j )
{
tmp=crcdata&0x0001;
crcdata=crcdata>>1;
if(tmp){
crcdata=crcdata^0xA001;
}
}
}
returncrcdata;
}
RS485 Stepper Motor Controller Manual
more Information on detail, please feel free to contact me
- Availability: In Stock
- Model: IS14010
- Brand: Adampower